Concrete Anchor Shear Calculator (USA)
✓ 100% Free
Concrete Anchor Shear
Calculator USA — ACI 318 Chapter 17 Anchor Design
All-in-one concrete anchor shear calculator for the USA — calculate steel shear capacity (φVsa), concrete breakout strength in shear (φVcb), pryout strength (φVcp), and minimum edge distance for cast-in and post-installed anchors per ACI 318-19 Chapter 17. Covers single anchors, edge distance correction factors, and governing failure mode identification for US structural and non-structural anchor design.
φ0.65
Steel Shear — Ductile Anchor (ACI 318-19 §17.6.1)
φ0.70
Concrete Breakout Shear — φ Factor (ACI 318 §17.6.2)
3 Modes
Steel · Breakout · Pryout — Governing Mode Controls
6ca1
Min. Member Thickness for Full Breakout — ACI 318 §17.6.2
⚡ Steel Shear (φVsa)
💥 Concrete Breakout (φVcb)
🔄 Pryout Strength (φVcp)
📏 Edge Distance Check
🔩 Cast-In · Post-Installed
⚖️ ACI 318-19 Ch. 17
A concrete anchor shear calculator for the USA determines the design shear capacity of anchors embedded in concrete per ACI 318-19 Chapter 17 (formerly ACI 318-14 Chapter 17 / Appendix D). Anchor shear design involves checking three independent failure modes and taking the lowest (governing) capacity: (1) Steel shear failure — φVsa = φ × 0.6 × Ase,V × futa, where the anchor steel shears off; (2) Concrete breakout in shear — φVcb = φ × (AVc/AVc0) × ψed,V × ψc,V × ψh,V × Vb, where a cone of concrete breaks out toward the free edge; and (3) Pryout — φVcp = φ × kcp × Ncp, which governs for short, stiff anchors loaded away from a free edge. Used by structural engineers, EITs, and detailers for US anchor design in structural connections, equipment anchorage, façade attachments, and safety-critical applications.
⚡ Concrete Anchor Shear Calculator — USA (ACI 318-19 Ch. 17)
Select a calculation tab — Steel Shear, Concrete Breakout, or Pryout — all per ACI 318-19 Chapter 17 for single anchors.
A_se,V = net tensile stress area of the anchor bolt — see ASME B1.1 thread tables or anchor mfr. data. Example: 1/2″ dia. A307 bolt ≈ 0.142 in²
f_uta ≤ 1.9 × f_ya and ≤ 125,000 psi per ACI 318-19 §17.6.1.2 for ductile steel anchors
Ductile steel: f_uta ≤ 1.9 × f_ya AND elongation ≥ 14% AND reduction in area ≥ 30% per ACI 318-19 §17.2.3
Enter 1 for single anchor — for anchor groups, this calculator computes total group steel shear capacity
V_u = factored shear per anchor from structural analysis (1.2D + 1.6L per ASCE 7 / ACI 318-19 §5.3). Enter 0 to skip demand check.
For SDC C–F, ACI 318-19 §17.10 requires additional ductility checks and limits φ factors for post-installed anchors
c_a1 = distance from anchor centerline to the free concrete edge in the direction of applied shear — the critical dimension controlling breakout
c_a2 = perpendicular edge distance. If c_a2 ≥ 1.5×c_a1 (or no perp. edge), the edge effect factor ψ_ed,V = 1.0
h_a = thickness of the concrete member. Member thickness correction ψ_h,V applies when h_a < 1.5×c_a1
l_e = min(h_ef, 8×d_a) for headed bolts — embedment depth up to 8 anchor diameters governs Vb. Use actual embedment for post-installed.
Nominal anchor shaft diameter — used in the V_b basic breakout strength equation
ACI 318-19 limits f’c to 10,000 psi for normal-weight concrete in Chapter 17 calculations
Use cracked concrete (1.0) unless analysis confirms uncracked conditions at service load in the anchor zone
Enter applied V_u to check φVcb ≥ Vu — leave 0 to calculate capacity only
N_cp = N_cb (single anchor) or N_cbg (group) — calculated per ACI 318-19 §17.6.2 in tension. Use anchor tension breakout calculator for this value.
h_ef = effective embedment depth of the anchor. k_cp = 1.0 for h_ef < 2.5 in., k_cp = 2.0 for h_ef ≥ 2.5 in. per ACI 318-19 §17.6.3
Use φ = 0.55 for seismic design categories C–F when Condition B applies (supplemental reinforcement not provided)
Enter applied V_u to check φVcp ≥ Vu — pryout typically governs for short anchors (< 2.5 in. embedment) loaded away from a free edge
Result
—
Per ACI 318-19 Chapter 17
📐 Calculation Breakdown
✅ ACI 318 Compliance
🔩 Concrete Anchor Shear — Failure Modes & Key Dimensions (ACI 318-19 Ch. 17)
📋 Key ACI 318 Chapter 17 Anchor Dimensions
ca1Edge dist. in shear direction (in.)
ca2Perpendicular edge distance (in.)
haMember (concrete) thickness (in.)
hefEffective embedment depth (in.)
leLoad-bearing length = min(h_ef, 8d_a)
daAnchor nominal diameter (in.)
Ase,VEffective shear area (in²)
AVcProjected area of breakout cone (in²)
φVsa=φ×0.6AsefutaSteel Shear Failure
|
φVcb=φ×(AVc/AVc0)×ψ×VbBreakout Failure
|
φVcp=φ×kcp×NcpPryout Failure
φ=0.65
Steel shear — ductile anchors (ACI 318-19 §17.5.3)
φ=0.70
Concrete breakout & pryout shear (ACI 318-19 §17.5.3)
min(3)
Governing = min(φVsa, φVcb, φVcp) per ACI 318 §17.6
Anchor Shaft
Bearing Plate / Shear Force
Concrete Breakout Cone
Effective Embedment h_ef
Free Edge
What is Concrete Anchor Shear Design per ACI 318-19 Chapter 17?
Concrete anchor shear design per ACI 318-19 Chapter 17 (the unified anchor design chapter, formerly Appendix D) establishes the design procedure for all anchors — cast-in-place headed bolts, J-bolts, and post-installed mechanical or adhesive anchors — subject to shear loads parallel to the concrete surface. ACI 318-19 Chapter 17 requires the engineer to check all applicable failure modes and use the lowest capacity as the governing strength. For shear, the three failure modes are steel shear failure at the anchor cross-section, concrete breakout toward the nearest free edge, and pryout failure for short stiff anchors. The design must satisfy φVn ≥ Vu for each mode, where Vu is the factored shear demand from ASCE 7-22 load combinations.
🔵 ACI 318-19 Chapter 17 Anchor Shear — Three Failure Modes Explained
Steel shear (§17.6.1): The anchor shaft yields and fractures in shear — governed by anchor steel area Ase,V and ultimate strength futa. This mode usually governs for large-diameter, deeply embedded anchors far from a free edge. Concrete breakout in shear (§17.6.2): A half-pyramid cone of concrete breaks out toward the nearest free edge — governed by edge distance ca1, member thickness ha, and concrete strength f’c. This mode almost always governs when an anchor is close to a free edge. Pryout (§17.6.3): The anchor pries out a concrete plug on the side opposite the shear direction — governs for short, rigid anchors (hef < 2.5 in.) loaded away from a free edge. ACI 318-19 §17.6 requires the engineer to check all three and use the minimum.
📏 Minimum Edge Distance — ACI 318-19 §17.9
ACI 318-19 Section 17.9.1 requires a minimum edge distance of cmin = max(hef/1.5, 6da, specific anchor product requirements). For post-installed anchors, the manufacturer’s ICC-ES evaluated minimum edge distance governs. Critical edge distances for concrete breakout: when ca1 < 1.5×hef, the projected breakout area is reduced below the full cone, dramatically reducing φVcb. The most effective way to increase concrete breakout capacity near an edge is to increase ca1 — moving the anchor further from the free edge increases capacity as ca11.5.
🔩 Cast-In vs. Post-Installed Anchors
Cast-in anchors (ASTM F1554 headed bolts, hooked bolts, J-bolts, welded headed studs) are placed before concrete placement and develop full ACI 318 strength from the embedded head bearing. Post-installed mechanical anchors (expansion anchors, undercut anchors — ASTM F1554) and adhesive anchors (ASTM C881 epoxy, ASTM E488) are installed in drilled holes after concrete hardens. ACI 318-19 requires post-installed anchors to be qualified per ACI 355.2 (mechanical) or ACI 355.4 (adhesive) with published ICC-ES Evaluation Report values for all failure modes. Post-installed adhesive anchors require special inspection for overhead and sustained tensile load conditions.
⚡ Seismic Anchor Design — ACI 318-19 §17.10
For anchors in Seismic Design Categories C–F, ACI 318-19 Section 17.10 imposes additional requirements: (1) anchors must be designed for 1.2× the design seismic shear; (2) post-installed anchors must be classified as Category 1 (for SDC C–F) per ACI 355.2/355.4 with enhanced ductility testing; (3) φ factors are reduced — φ = 0.70 for steel shear (vs. 0.65/0.60 for non-seismic), and φ = 0.55 for concrete breakout in SDC C–F Condition B. Supplementary reinforcement can restore the higher φ factors. Seismic provisions apply to any anchor resisting earthquake effects, including diagonal strut and collector connections.
ACI 318-19 Chapter 17 Anchor Shear Design Formulas (USA)
The complete ACI 318-19 Chapter 17 formula set for all three anchor shear failure modes — in US customary units (inches, pounds, kips). These formulas govern all US structural anchor design for cast-in and post-installed anchors under IBC 2021, ASCE 7-22, and ACI 318-19.
⚡ ACI 318-19 Chapter 17 — Complete Anchor Shear Formula Set
MODE 1 — STEEL SHEAR FAILURE (ACI 318-19 §17.6.1):
Vsa = 0.6 × Ase,V × futa [lb, with Ase,V in in², futa in psi]
φVsa = φ × Vsa (φ=0.65 ductile, φ=0.60 brittle)
futa limit: futa ≤ min(1.9×fya, 125,000 psi) for ductile classification
MODE 2 — CONCRETE BREAKOUT IN SHEAR (ACI 318-19 §17.6.2):
Basic breakout strength (single anchor):
Vb = min[7×(le/da)^0.2 × √da × λ×√f’c × ca1^1.5, 9λ×√f’c × ca1^1.5] [lb]
AVc0 = 4.5 × ca1² [full projected area, in²]
AVc = min(1.5ca1, ca2+1.5ca1) × min(1.5ca1, ha) [projected area, in²]
ψed,V = 1.0 if ca2 ≥ 1.5ca1 | ψed,V = 0.7 + 0.3×ca2/(1.5ca1) if ca2 < 1.5ca1
ψc,V = 1.4 (uncracked) | 1.0 (cracked — default)
ψh,V = √(1.5ca1/ha) ≥ 1.0 [only if ha < 1.5ca1]
Vcb = (AVc/AVc0) × ψed,V × ψc,V × ψh,V × Vb
φVcb = φ × Vcb (φ = 0.70 non-seismic | φ = 0.55 seismic Cond. B)
MODE 3 — PRYOUT SHEAR (ACI 318-19 §17.6.3):
kcp = 1.0 (hef < 2.5 in.) | kcp = 2.0 (hef ≥ 2.5 in.)
Vcp = kcp × Ncp [Ncp = Ncb from tension breakout calc.]
φVcp = φ × Vcp (φ = 0.70)
GOVERNING SHEAR CAPACITY (use minimum of all applicable modes):
φVn = min(φVsa, φVcb, φVcp) ≥ Vu ✓
⚠️ ACI 318-19 Chapter 17 Interaction — Combined Tension and Shear
When an anchor is subject to both tension (Nu) and shear (Vu) simultaneously, ACI 318-19 Section 17.8 requires an interaction check. The interaction equation is: (Nua/φNn)5/3 + (Vua/φVn)5/3 ≤ 1.0. A simplified check: if Nua ≤ 0.2×φNn, full shear capacity φVn may be used; if Vua ≤ 0.2×φVn, full tension capacity φNn may be used. This interaction check is separate from and in addition to the individual mode capacity checks. This calculator addresses shear only — perform the combined tension+shear interaction check separately when axial loads are also present.
Anchor Shear Quick-Reference — Common Anchor Sizes (ACI 318-19, 4 ksi Concrete)
Pre-calculated steel shear capacity (φVsa) and concrete breakout capacity (φVcb) for common US anchor bolt sizes and edge distances — ASTM F1554 Grade 55 / ASTM A193 B7 steel, f’c = 4,000 psi, normal-weight cracked concrete, no perpendicular edge effects.
| Anchor Dia. | Ase,V (in²) | futa | φVsa (kips) | ca1 = 4″ | ca1 = 6″ | ca1 = 8″ | Typical Use |
|---|---|---|---|---|---|---|---|
| 1/2 in. | 0.142 in² | 120 ksi | 6.1 k | 2.1 k | 3.8 k | 5.9 k | Light equipment, façade clips |
| 5/8 in. | 0.226 in² | 120 ksi | 9.7 k | 2.4 k | 4.4 k | 6.9 k | Equipment pads, sill plates |
| 3/4 in. | 0.334 in² | 120 ksi | 14.4 k | 2.8 k | 5.1 k | 7.9 k | Column base plates, handrails |
| 7/8 in. | 0.462 in² | 120 ksi | 19.9 k | 3.1 k | 5.7 k | 8.9 k | Structural column bases |
| 1 in. | 0.606 in² | 120 ksi | 26.1 k | 3.5 k | 6.4 k | 9.9 k | Heavy structural connections |
| 1-1/4 in. | 0.969 in² | 120 ksi | 41.7 k | 4.0 k | 7.3 k | 11.3 k | Moment frame base plates |
| 1/2 in. | 0.142 in² | 75 ksi | 3.8 k | 2.1 k | 3.8 k | 5.9 k | Light-duty F1554 Gr.36/55 |
3/4 in. Anchor — 120 ksi (A193 B7)
A_se,V0.334 in²
φVsa (Steel Shear)14.4 kips
φVcb @ c_a1 = 4 in.2.8 kips
φVcb @ c_a1 = 6 in.5.1 kips
φVcb @ c_a1 = 8 in.7.9 kips
1 in. Anchor — 120 ksi (A193 B7)
A_se,V0.606 in²
φVsa (Steel Shear)26.1 kips
φVcb @ c_a1 = 6 in.6.4 kips
φVcb @ c_a1 = 8 in.9.9 kips
Governing Mode (6 in. edge)Breakout (6.4 k)
5/8 in. Anchor — 75 ksi (F1554 Gr.55)
A_se,V0.226 in²
φVsa (Steel Shear)6.1 kips
φVcb @ c_a1 = 6 in.4.4 kips
φVcb @ c_a1 = 8 in.6.9 kips
Key ACI 318-19 Chapter 17 Anchor Shear Concepts — USA
📏
Supplementary Reinforcement — Restoring φ
ACI 318-19 §17.5.3 defines two conditions: Condition A (supplementary reinforcement present — hairpins or U-bars enclosing the anchor, developed beyond the failure plane) uses higher φ factors (φ = 0.75 for concrete breakout in shear vs. 0.70). Condition B (no supplementary reinforcement) uses the standard lower φ factors. For edge anchors close to a free edge, adding a hairpin reinforcement bar (typically #4 or #5 U-bar behind the anchor) can both raise φ and significantly improve breakout capacity beyond what ACI 318-19 §17.6.2 calculates for plain concrete.
🔩
Anchor Groups — Shear Distribution
For anchor groups (two or more anchors with spacing ≤ 3ca1), ACI 318-19 §17.6.2.1 requires checking the group concrete breakout capacity Vcbg using the total projected area AVc for the entire group divided by AVc0 for a single anchor, multiplied by the eccentricity factor ψec,V = 1/(1 + 2e’V/(3ca1)) ≤ 1.0, where e’V is the distance between the resultant shear force and the centroid of the anchor group. This calculator is for single anchors only — use ACI 318-19 §17.6.2.1 directly for group design.
⚡
Shear Perpendicular vs. Parallel to Edge
ACI 318-19 §17.6.2.1(c) provides a special provision when shear is applied parallel to a free edge rather than toward it: the breakout strength Vcb may be taken as twice the value calculated for shear toward the edge at the same edge distance. This doubles the concrete breakout capacity for parallel-to-edge shear, which is highly beneficial for anchors in concrete walls or edges where shear acts along the wall rather than perpendicular to it — a frequently overlooked provision that can significantly increase design capacity.
🏗️
Column Base Plate Anchor Design
Column base plate anchor bolts in the USA are typically ASTM F1554 (Grade 36, 55, or 105) cast-in-place headed bolts or J-bolts. For moment-frame base plates, the anchor shear demand is determined from the column shear V and any amplified seismic forces per AISC 341 and ASCE 7-22. Minimum edge distance per AISC Design Guide 1 (Base Plate and Anchor Rod Design) is typically 5 × da for fabricated base plates. The governing failure mode for column base anchors is usually steel shear or pryout when anchors are centered on the base plate well away from the concrete edge — concrete breakout governs only at slab edges or piers.
✅ Pro Tip — Maximizing Anchor Shear Capacity in the USA
US structural engineers use these strategies to maximize concrete anchor shear capacity: (1) Increase ca1 — breakout capacity increases as ca11.5, so doubling edge distance increases breakout by ~2.8×; (2) Add hairpin reinforcement — a #4 or #5 U-bar around the anchor shifts failure from brittle breakout to ductile steel or reinforcement yielding; (3) Use larger anchor diameter — increases steel shear as Ase,V; (4) Increase concrete strength — breakout increases as √f’c; (5) Verify uncracked condition — if the zone around the anchor is demonstrably uncracked under service loads, ψc,V = 1.4 increases breakout by 40%. For edge anchors, increasing ca1 and adding hairpin bars is almost always the most cost-effective solution.
🚨 This Calculator Is for Preliminary Design Only — Licensed PE Required
This anchor shear calculator uses simplified single-anchor ACI 318-19 Chapter 17 formulas for preliminary design checks. It does not perform: anchor group design, combined tension-shear interaction (§17.8), adhesive anchor bond strength (§17.6.5), seismic anchor qualification (§17.10), ICC-ES ESR
product compliance verification, supplementary reinforcement design (Condition A),
concrete side-face blowout (§17.6.4), anchor group eccentricity factor (ψ_ec,V),
or AISC base plate design per Design Guide 1. All US structural anchor designs
must be designed, detailed, and stamped by a licensed Professional Engineer (PE)
per ACI 318-19 Chapter 17, IBC 2021, and all applicable state and local codes.
Post-installed anchors require ICC-ES Evaluation Service Reports (ESR) confirming
qualification per ACI 355.2 or ACI 355.4 for the specific installation conditions.
❓ Concrete Anchor Shear Calculator FAQ — USA (ACI 318-19)
What is the ACI 318-19 Chapter 17 formula for concrete anchor steel shear capacity?
+
ACI 318-19 §17.6.1 steel shear capacity step-by-step:
- Basic strength: Vsa = 0.6 × Ase,V × futa (lbs, with Ase,V in in² and futa in psi)
- futa limit: futa ≤ min(1.9 × fya, 125,000 psi) for ductile classification
- φ factor: φ = 0.65 (ductile steel) | φ = 0.60 (brittle/non-ductile steel)
- Design capacity: φVsa = φ × 0.6 × Ase,V × futa
- Example — 3/4 in. A193 B7 anchor: Ase,V = 0.334 in², futa = 125,000 psi (capped) → Vsa = 0.6 × 0.334 × 125,000 = 25,050 lb → φVsa = 0.65 × 25,050 = 16.3 kips
- Steel shear typically governs for deeply embedded anchors far from a free edge — concrete breakout governs near edges
- For anchor groups: multiply φVsa × number of anchors (assuming equal load distribution)
What is concrete breakout in shear and when does it govern per ACI 318?
+
Concrete breakout in shear (ACI 318-19 §17.6.2) governs when an anchor is close to a free edge:
- Breakout cone shape: A half-pyramid of concrete breaks out from the anchor toward the nearest free concrete edge in the direction of applied shear
- Basic breakout strength Vb: = min[7×(le/da)0.2×√da×λ√f’c×ca11.5, 9λ√f’c×ca11.5] (lb)
- Area ratio AVc/AVc0: accounts for limited edge distances or member thickness reducing the available breakout area below the full AVc0 = 4.5ca1²
- When it governs: almost always when ca1 < 8× anchor diameter — breakout capacity is very sensitive to edge distance
- Key rule of thumb: φVcb ≈ 1.8 × ca11.5 × √f’c × 0.001 (kips) for a single anchor with no edge/thickness reductions — edge distance is the dominant variable
- Concrete breakout in shear is the most common governing failure mode for US anchor designs in structural and architectural applications
What is pryout failure in anchor shear design per ACI 318-19?
+
Pryout failure (ACI 318-19 §17.6.3) is a concrete failure mode unique to shear loading:
- Mechanism: A short, stiff anchor loaded in shear tends to rotate — the anchor head or embedded tip pries out a cone of concrete on the opposite side from the applied shear direction
- Formula: Vcp = kcp × Ncp, where Ncp = concrete breakout strength in tension (Ncb) calculated per ACI 318-19 §17.6.2
- kcp = 1.0 for hef < 2.5 in. | kcp = 2.0 for hef ≥ 2.5 in.
- φ factor: φ = 0.70 (non-seismic) | φ = 0.55 (SDC C–F, Condition B)
- When it governs: Short, rigid anchors (hef < 3–4 in.) loaded in shear away from a free edge — common for headed studs welded to steel plates, short cast-in bolts in thick walls
- For longer anchors (hef ≥ 2.5 in.) with kcp = 2.0, pryout rarely governs if the anchor is near a free edge — breakout toward the edge dominates
What are the ACI 318-19 φ (phi) factors for anchor shear design?
+
ACI 318-19 §17.5.3 strength reduction factors (φ) for anchor shear — USA:
- Steel shear — ductile anchor (Condition A or B): φ = 0.65
- Steel shear — brittle anchor (Condition A or B): φ = 0.60
- Concrete breakout in shear — Condition A (supplementary reinforcement): φ = 0.75
- Concrete breakout in shear — Condition B (no supplementary reinforcement): φ = 0.70
- Pryout — Condition A: φ = 0.75 | Condition B: φ = 0.70
- Seismic (SDC C–F) — Concrete breakout/pryout, Condition B: φ = 0.55
- Condition A (higher φ) applies only when supplementary reinforcement (hairpin U-bars or stirrups enclosing the anchor, developed ≥ ld beyond the failure plane) is provided and properly detailed per ACI 318-19 §17.5.3
What ASTM specifications are used for anchor bolts in US construction?
+
Common ASTM anchor bolt specifications used in US construction per ACI 318-19 and AISC:
- ASTM F1554 Grade 36: Fu = 58–80 ksi depending on diameter — most common for light-duty cast-in anchor bolts; weldable
- ASTM F1554 Grade 55: Fu = 75 ksi — medium-duty structural anchor bolts; also weldable with supplement S1
- ASTM F1554 Grade 105: Fu = 125 ksi — high-strength anchor bolts for column base plates and heavy structural connections; not weldable
- ASTM A193 Grade B7 (threaded rods): Fu = 125 ksi — very common for heavy industrial base plates and equipment anchors
- ASTM A307 Grade A: Fu = 60 ksi — standard hex bolts; used for non-structural and light-duty applications
- ASTM A325 / A490 (structural bolts): Fu = 120/150 ksi — primarily for steel-to-steel connections, occasionally used as post-installed anchors in special applications
- AISC Design Guide 1 (Base Plate and Anchor Rod Design) recommends ASTM F1554 Gr. 36 or 55 for most column base plate anchor rods in the USA
How does edge distance affect concrete anchor shear capacity in ACI 318?
+
Edge distance ca1 is the single most critical variable in anchor shear breakout design:
- Breakout capacity scales as ca11.5: Doubling edge distance from 4 in. to 8 in. increases φVcb by 21.5 = 2.83× — nearly triples the capacity
- Full breakout area: Requires ha ≥ 1.5×ca1 AND ca2 ≥ 1.5×ca1 — if either is less, AVc < AVc0 and capacity is reduced
- Minimum edge distance (ACI 318-19 §17.9.1): cmin = max(hef/1.5, 6da) for cast-in anchors
- Post-installed anchors: Manufacturer ICC-ES ESR minimum edge distance governs — always check ESR for product-specific minimums
- Practical rule: For maximum φVcb ≈ φVsa (breakout capacity equals steel capacity), target ca1 ≈ (φVsa/(1.8×0.70×λ√f’c))2/3 — this gives the minimum edge distance for steel shear to govern over breakout
- When ca1 cannot be increased (existing structure), adding hairpin reinforcement is the most cost-effective capacity upgrade
🔗 Related Concrete & Anchor Calculators — USA
Anchor Tension Calculator
ACI 318 Ch. 17 anchor tension breakout, pullout, and side-face blowout
Column Base Plate Calculator
AISC Design Guide 1 base plate sizing and anchor bolt design
Concrete Beam Shear Calculator
ACI 318-19 beam shear capacity — Vc, Vs, stirrup spacing
Circular Slab Calculator
ACI 318 round slab thickness, volume, and temperature steel
Trusted US Anchor Design Standards & Resources
Official ACI, AISC, and ICC codes and references for US concrete anchor shear design
📘
ACI 318-19 Chapter 17
§17.6.1 · §17.6.2 · §17.6.3 · §17.10
ACI 318-19 Chapter 17 is the primary US standard governing all concrete anchor design — cast-in and post-installed, for all failure modes in tension and shear. It replaced ACI 318 Appendix D in the 2014 edition and is referenced by IBC 2021 as the mandatory anchor design standard for all US structural and non-structural anchors in reinforced concrete.
AISC Design Guide 1
Base Plate & Anchor Rod Design · 2nd Ed.
AISC Design Guide 1 (Base Plate and Anchor Rod Design, 2nd Edition) provides comprehensive guidance for US column base plate and anchor bolt design, integrating ACI 318 Chapter 17 anchor provisions with AISC 360 steel design. It covers anchor rod sizing, edge distance requirements, grout pad design, shear lug design, and seismic considerations for moment and braced frame base plates.
ICC-ES Evaluation Reports
ACI 355.2 · ACI 355.4 · ESR Product Reports
ICC Evaluation Service (ICC-ES) publishes Evaluation Service Reports (ESRs) for post-installed anchor products, confirming compliance with ACI 355.2 (mechanical anchors) or ACI 355.4 (adhesive anchors). ESR reports contain product-specific characteristic strengths, minimum edge distances, embedment depths, and installation requirements that supplement or modify the ACI 318-19 Chapter 17 calculated values for specific proprietary anchor products.